Square D QO QO120CAFIC Circuit Breaker, AFCI, 20 A, 1 -Pole, 120/240 V, Fixed Trip, Plug Mounting

Category Breakers
100794150

Square D QO QO120CAFIC Circuit Breaker, AFCI, 20 A, 1 -Pole, 120/240 V, Fixed Trip, Plug Mounting

Item Code: 100794150
Category Breakers
Manufacturer SQUARE D

Description

Combination CAFCI 3/4 in single-pole circuit breaker, designed for overload and over-current protection of an electrical system. Thermal-magnetic tripping mechanism. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. Visi-Trip indicator to identify which circuit is out in the load center. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. 10kA interrupting rating. Uses one space per breaker. 120 VAC. UL listed. Carded.

Specifications

UNSPSC Code

35.353.353

Weight

1lb

Height

6.9in

Width

3.7in

Length

4.6in

Brand

Square D

Category

FUSES & BREAKERS

Current Rating

20 A

Dimensions

2-29/32 in L x 3/4 in W x 4-3/4 in H

Interrupt Rating

10 kA

Mounting Type

Plug

Number of Phases

1

Number Of Poles

1

Number of Spaces

1

Terminal Type

Pressure Contact

Trip Type

Fixed

Type

AFCI

Voltage Rating

120/240 V

Wire Size

12 to 8 14 to 8 AWG

Not Stocked at this Branch
Starting from
$81.29 / EA
/
- +
Pick Up from (click to change) Barbur, Portland

Square D QO QO120CAFIC Circuit Breaker, AFCI, 20 A, 1 -Pole, 120/240 V, Fixed Trip, Plug Mounting

Category Breakers
100794150

Square D QO QO120CAFIC Circuit Breaker, AFCI, 20 A, 1 -Pole, 120/240 V, Fixed Trip, Plug Mounting

Item Code: 100794150
Category Breakers
Manufacturer SQUARE D

Description

Combination CAFCI 3/4 in single-pole circuit breaker, designed for overload and over-current protection of an electrical system. Thermal-magnetic tripping mechanism. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. Visi-Trip indicator to identify which circuit is out in the load center. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. 10kA interrupting rating. Uses one space per breaker. 120 VAC. UL listed. Carded.

Specifications

UNSPSC Code

35.353.353

Weight

1lb

Height

6.9in

Width

3.7in

Length

4.6in

Brand

Square D

Category

FUSES & BREAKERS

Current Rating

20 A

Dimensions

2-29/32 in L x 3/4 in W x 4-3/4 in H

Interrupt Rating

10 kA

Mounting Type

Plug

Number of Phases

1

Number Of Poles

1

Number of Spaces

1

Terminal Type

Pressure Contact

Trip Type

Fixed

Type

AFCI

Voltage Rating

120/240 V

Wire Size

12 to 8 14 to 8 AWG